Disc Tube Reverse Osmosis Membrane Element
membrane performance parameters
|
model |
CPDT-75 | CPDT-90 | CPDT-120 | |
|
Max operating pressure (bar) |
75 |
90 | 120 | |
|
Test pressure (bar) |
50±1 |
65±1 | 85±1 | |
| Salt rejection (%) | 99% | 99% | 90%~97% | |
|
Test flow |
250 L/H |
|||
|
Circulation flow |
800±100 L/H |
|||
|
Max operating temperature |
40 °C |
|||
|
Transmembrane pressure |
4-8 bar |
|||
|
pH range (continuous operation) |
5-9 |
|||
|
Cleaning pH range |
2-12 |
|||
|
Feed flow rate (L/element) |
800-1000 |
|||
Application Scenarios
- High-salinity industrial wastewater volume reduction
- Pharmaceutical fermentation, fine chemical & pesticide intermediate wastewater
- Mine high-salinity wastewater desalination and resource recovery
- Power plant FGD desulfurization wastewater & ZLD projects
- Landfill leachate and biogas slurry concentration

Related Knowledge
Types of Membrane Fouling
Adsorption Fouling
Organics adsorb onto the membrane surface. Contaminants build up within membrane pores, shrinking pore size and raising membrane resistance. This fouling is difficult to remove. Main contaminants are dissolved substances and emulsions.
Scaling Fouling
Salts in raw water exceed solubility and precipitate as scale on membranes. Contaminants include colloids and particles: organics like fats, proteins and humic acid; inorganics such as calcium, magnesium, iron and phosphorus salts.
Biofouling
Microbes accumulate at the membrane-water interface in two phases: adhesion and growth. If biocide dosage is insufficient, attached microbes feed on nutrients and multiply to form biofilms, mainly bacteria and algae.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Disc Tube Reverse Osmosis Membrane Element, China Disc Tube Reverse Osmosis Membrane Element manufacturers, suppliers, factory, sanitary membrane biotech grade module, sanitary membrane element, sanitary membrane high hygiene module, sanitary membrane skid system, spiral wound membrane filtration module, spiral wound membrane ion rejection module