Sanitary Spiral UF Membrane Element

Brand Name: NANOIMP
OEM/ODM: Accept
Manufacturer: Yes
Delivery Time: 3-15 days
Shipping Support: Express / Sea/ Land
Place of Origin: Hangzhou, China
E-mail: lena.hu@nano-sepmer.com
Model: UF1-8040/34SU | UF2-8040 /34SU | UF3-8040 /34SU | UF4-8040 /32SU
Technical Parameters
|
model |
UF1-8040/34SU |
UF2-8040 /34SU | UF3-8040 /34SU | UF4-8040 /32SU | |
| Molecular Weight Cut-off (MWCO) | 5kDa | 10kDa | 30kDa | 50kDa | |
| Membrane Material | PES | PES | PES | PES | |
| Membrane area (ft2/m2) | 365(34)±3% | 365(34)±3% | 365(34)±3% | 376(35) ±3% | |
| Operating Pressure (psi/bar) |
75-220 ( 5-15) |
45-150 (3-10) |
30-100 ( 2-7) |
30-100 ( 2-7) |
|
| Operating Flux (LMH) | 5-30 | ||||
| Temperature Resistance (℃) | ≤45 | ||||
| Max Operating Pressure (psi/bar) | 100(7) | ||||
| Continuous Operating pH | 1-13 | ||||
| Operating Temperature (℃) | 5-45 | ||||
|
Custom Size Available |
1812/3838/4038/4040/8038/8040 | ||||
Product Dimensions
|
Membrane element size |
A (±2.0mm) |
B (±0.5mm) |
C (±0.1mm) |
| 1812 | 305 | 15.7 | 45 |
| 3838 | 965 | 21.0 | 97 |
| 4038 | 965 | 12.8 | 100 |
| 4040 | 1016 | 19.0 | 100 |
| 8038 | 965 | 28.8 | 200 |
| 8040 | 1016 | 28.8 | 200 |



Application Scenarios
- Food and Beverage: Clarification, impurity removal, purification and concentration of fruit juice, plant extracts and syrup to remove colloids and suspended solids.
- Bio-fermentation: Bacterial cell separation, purification and concentration of bioactive substances from fermentation broth.
- Pharmaceutical Industry: Filtration, impurity removal, purification and concentration of pharmaceutical liquid and intermediates to meet hygienic production requirements.
- Dairy Processing: Separation, purification and concentration of whey protein and other materials to improve material utilization.
- Condiment Refining: Clarification and impurity removal of soy sauce and vinegar to enhance liquid clarity and stability.
- Plant Extraction: Purification of Chinese herbal and plant polysaccharide extracts, purification and concentration of active ingredients.

Related Knowledge
Judgment of Membrane Fouling
How to identify membrane fouling. Key parameters are listed below:
(1) The most critical indicator is the difference in membrane flux (units such as LMH or LPM) under identical operating conditions (same pressure, temperature and recirculation flow rate). Generally, membrane fouling is confirmed when the flux of used membranes drops below 85% of that of new membranes.
(2) Membrane fouling usually leads to changes in membrane rejection performance, which may either increase or decrease.
(3) Under identical operating conditions, the pressure difference across the membrane module rises after fouling, which means the transmembrane resistance increases.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Sanitary Spiral UF Membrane Element- PES, China Sanitary Spiral UF Membrane Element- PES manufacturers, suppliers, factory, sanitary membrane particle removal module, sanitary membrane pharmaceutical water module, sanitary membrane post treatment module, sanitary membrane sanitary process system, Sanitary Spiral RO Membrane, spiral wound membrane c ip compatible module