lena.hu@nano-sepmer.com    +8618379535954
Cont

Have any Questions?

+8618379535954

Sanitary Spiral Wound RO Membrane Element
video
Sanitary Spiral Wound RO Membrane Element

Sanitary Spiral Wound RO Membrane Element

- Hygiene-grade spiral wound reverse osmosis element for high purity water generation
- Certified for food contact applications, suitable for sensitive production environments
- Constructed with PSU components and PP mesh cage for hygienic operation
- Supports multiple RO flat sheet types for tap, brackish and saltwater treatment
- Multiple customizable physical sizes to fit various membrane housing assemblies
Send Inquiry

Product Introduction

Sanitary Spiral Wound RO Membrane Element

Decolorization Dedicated Sanitary Spiral NF Membrane For High-Pigment Feed Liquid

Brand Name: NANOIMP

OEM/ODM: Accept

Manufacturer: Yes

Delivery Time: 3-15 days

Shipping Support: Express / Sea/ Land

Place of Origin: Hangzhou, China

E-mail: lena.hu@nano-sepmer.com

Main Models: ROA-8040/34SU | ROB-8040/34SU

 

Key Measured Performance Metrics for Sanitary Spiral‑RO Elements

 

Test Parameter

ROA-8040/34SU

ROB-8040/34SU

Ratio of desalinization

99.3%

99.8%

Active Filtration Surface

365(34)±3%

Temperature tolerance (°C)

≤45

Upper Working Pressure Limit (bar)

≤50

Normal Operating pH

2-10

Clean pH

1-13

Customizable Element Sizes

1812/3838/4038/4040/8038/8040

 

Element Outer Dimension Data

 

2

Membrane element size

A (±2.0mm)

B (±0.5mm)

C (±0.1mm)

1812

305

15.7 (inner diameter)

45

3838

965

21.0

97

8038

965

28.8 (inner diameter)

200

8040

1016

28.8 (inner diameter)

200

 

Related Knowledge

Judgment of Membrane Fouling
 

How to identify membrane fouling. Key parameters are listed below:

(1) The most critical indicator is the difference in membrane flux (units such as LMH or LPM) under identical operating conditions (same pressure, temperature and recirculation flow rate). Generally, membrane fouling is confirmed when the flux of used membranes drops below 85% of that of new membranes.

(2) Membrane fouling usually leads to changes in membrane rejection performance, which may either increase or decrease.

(3) Under identical operating conditions, the pressure difference across the membrane module rises after fouling, which means the transmembrane resistance increases.

Warranty Period

The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:

The date when the reverse osmosis system is put into operation;

Six 6 months from the date the membrane elements are shipped from the manufacturing site;

Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.

Hot Tags: Sanitary Spiral Wound RO Membrane Element, China Sanitary Spiral Wound RO Membrane Element manufacturers, suppliers, factory, sanitary membrane assembly, sanitary membrane clean water module, sanitary membrane sterilizable module, Sanitary Spiral NF Membrane, spiral wound membrane drinking water module, spiral wound membrane unit

Send Inquiry

(0/10)