lena.hu@nano-sepmer.com    +8618379535954
Cont

Have any Questions?

+8618379535954

Food Safe Spiral Wound NF Membrane Element
video
Food Safe Spiral Wound NF Membrane Element

Food Safe Spiral Wound NF Membrane Element

Qualification: FDA food contact compliance certification
Structure: Spiral wound sanitary NF membrane, PSU accessories, PP mesh cage to reduce dead volume
Membrane Sheet: NF flat sheet, customizable molecular cut-off grades between 200~1000 Da
Size: Customizable element sizes: 1812,3838,4038,4040,8038,8040
Send Inquiry

Product Introduction

Food Safe Spiral Wound NF Membrane Element

 

NF Key Operating Parameter Sheet

 

model

NFA-8040/34SU

NFB-8040/34SU

Molecular cut off

200-300 Da

500-800 Da

Diaphragm Material

Piperazine

Membrane area (ft2/m2)

365(34)±3%

Flux (LMH)

5-20

Temperature tolerance (°C)

≤45

Operating pressure (bar)

≤50

Normal Operating pH

2-10

Clean pH

1-13

Customizable size

1812/3838/4038/4040/8038/8040

 

Product size parameter

Membrane element size

A (±2.0mm)

B (±0.5mm)

C (±0.1mm)

1812

305

15.7 

45

3838

965

21.0 (outer diameter)

97

4038

965

12.8 (outer diameter)

100

4040

1016

19.0 (outer diameter)

100

8038

965

28.8 

200

8040

1016

28.8

200

2.png3.png1.png

Related Knowledge

Types of Membrane Fouling
 

Adsorption Fouling

Organics adsorb onto the membrane surface. Contaminants build up within membrane pores, shrinking pore size and raising membrane resistance. This fouling is difficult to remove. Main contaminants are dissolved substances and emulsions.

Scaling Fouling

Salts in raw water exceed solubility and precipitate as scale on membranes. Contaminants include colloids and particles: organics like fats, proteins and humic acid; inorganics such as calcium, magnesium, iron and phosphorus salts.

Biofouling

Microbes accumulate at the membrane-water interface in two phases: adhesion and growth. If biocide dosage is insufficient, attached microbes feed on nutrients and multiply to form biofilms, mainly bacteria and algae.

Warranty Period

 

The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:

The date when the reverse osmosis system is put into operation;

Six 6 months from the date the membrane elements are shipped from the manufacturing site;

Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.

 

Hot Tags: Food Safe Spiral Wound NF Membrane Element, China Food Safe Spiral Wound NF Membrane Element manufacturers, suppliers, factory, sanitary membrane, sanitary membrane process skid module, sanitary membrane protein separation module, sanitary membrane sanitary process system, sanitary membrane skid system, spiral wound membrane ion rejection module

Send Inquiry

(0/10)