1. Structure: Acid-resistant spiral-wound nanofiltration membrane specially for acidic feed liquid, suitable for purification of various acids.
2. Membrane Sheet: Special acid-resistant nanofiltration membrane sheet, selectively intercepts ions and macromolecules with low performance attenuation.
3. Performance: Salt rejection 90%-98%, high acid recovery rate and stable separation efficiency.
4. Size: Multiple specifications available (2540/4040/8040)
Send Inquiry

Product Introduction

High Pressure Acid Resistant NF for Brine Lithium Extraction

 

Performance Data

 

model

ASNF1-8040/34FO ASNF2-8040/34FO
Membrane Area(ft2/m2) 365(34)±3%

Ratio of desalinization

75%-95%

Design Flux (LMH)

5-15

Max Operating Pressure(psi/bar) ≤510(35)
Max Operating Temperature (℃) ≤40
Single Element Pressure Differential (psi/bar) 15(1.0)

 

Product size parameters

 

Element Overall Dimensions

A (±2.0mm)

B (±0.5mm)

C (±0.1mm)

2540 1016 28.8 200

4040

1016

19.0

100

8040

1016

28.8

200

 

 .png

.png

Related Knowledge

 

Membrane Module Storage

 

System storage instructions:

Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.

Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.

If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.

If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.

If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below. The preservative solution shall be renewed every month.

 

Warranty Period

 

The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:

The date when the reverse osmosis system is put into operation;

Six 6 months from the date the membrane elements are shipped from the manufacturing site;

Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.

 