Low-Fouling Brackish Water RO Membrane Element
Product Performance Parameters
|
Model |
ROB-8040/34FA | ROB-8040/46FA |
|
Membrane area (ft2/m2) |
400(37)±3% | 300(27)±3% |
| Permeate Flux (GPD / m³·d) | 10500(41)±15% | 7600(30)±15% |
|
Test desalination rate (%) |
99.5% |
|
|
Max operating temperature (℃) |
≤45 |
|
| Max Operating Pressure (psi / bar) | ≤600(41) | |
| Recommended Cleaning Pressure (psi/bar) | 75-100 / 5.2-6.9 | |
|
Normal operation pH |
2-10 |
|
| Max Feed SDI | ≤5 | |
Application Scenarios
- Industry: Environmental protection, municipal water, chemical & coal chemical industry
- Feed Stream: Municipal secondary effluent, industrial park reclaimed water, cooling tower blowdown, brackish raw water with trace colloids
- Process Objective: Deep desalination, wastewater recycling, reduce freshwater intake
- Membrane Function: Block dissolved salts, colloids and suspended solids; suppress concentration polarization and ease repeated chemical cleaning
- Application Conditions: Feed needs proper pretreatment to remove suspended solids; operating pH 2–10; max pressure 41 bar, max temperature 45°C; avoid heavy oil and strong oxidants

FAQ
Q: What makes this membrane better for wastewater reuse and high-colloid feed?
A: Its parallel channel design eliminates dead zones and suppresses concentration polarization, which greatly slows pollutant accumulation. It tolerates frequent chemical cleaning to recover performance.
Q: What is the applicable pH range for routine operation and cleaning?
A: Normal operating pH ranges from 2 to 10. Chemical cleaning can be performed within this pH window to reverse fouling.
Q: What are the pressure and temperature limits for safe operation?
A: Max working pressure is 41 bar and max operating temperature is 45°C. Exceeding these limits will accelerate fouling and membrane degradation.
Related Knowledge
Membrane Module Storage
System storage instructions:
- Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.
- Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.
- If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.
- If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.
- If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below 3. The preservative solution shall be renewed every month.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Low-Fouling Brackish Water RO Membrane Element, China Low-Fouling Brackish Water RO Membrane Element manufacturers, suppliers, factory, Acid Resistant RO 8040, HSRO 8040, ro membrane multistage module, ro membrane polyamide module, ro membrane skid system, spiral wound membrane permeate channel module