Fouling-Resistant BWRO Membrane

Brand Name: NANOIMP
OEM/ODM: Accept
Manufacturer: Yes
Delivery Time: 3-15 days
Shipping Support: Express / Sea/ Land
Place of Origin: Hangzhou, China
E-mail: lena.hu@nano-sepmer.com
Main Models: ROB-8040/34FA | ROB-8040/46FA
Product Performance Parameters
|
Model |
ROB-8040/34FA | ROB-8040/46FA |
|
Membrane area (ft2/m2) |
400(37)±3% | 300(27)±3% |
| Permeate Flux (GPD / m³·d) | 10500(41)±15% | 7600(30)±15% |
|
Test desalination rate (%) |
99.5% |
|
|
Max operating temperature (℃) |
≤45 |
|
| Max Operating Pressure (psi / bar) | ≤600(41) | |
| Recommended Cleaning Pressure (psi/bar) | 75-100 / 5.2-6.9 | |
|
Normal operation pH |
2-10 |
|
| Max Feed SDI | ≤5 | |
Product size parameters
(1) Flat End

|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
|
8040 |
1016 |
28.8 |
200 |
(2) Protruding End

|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
D (±0.1mm) |
| 2540 | 1016 | 30.2 | 19.1 | 61 |
|
4040 |
1016 |
26.7 |
19.1 |
100 |
Application Scenarios
- Surface Water & Brackish Groundwater Purification: Treat slightly polluted surface water and brackish groundwater, remove salts, colloids and suspended solids to produce industrial process water.
- Cooling Tower Blowdown Reuse: Advanced desalination of cooling tower blowdown from power and chemical plants. The permeate can be reused in circulating water system to reduce raw water intake.
- Municipal & Industrial Park Reclaimed Water Reuse: Deep desalination for municipal secondary effluent and industrial park recycled water to produce reused industrial process pure water.
- Power Plant Boiler Feed Water Preparation: Raw water desalination and purification to produce boiler feed water and ensure stable operation of generator units.
- Chemical & Coal Chemical Process Water: Raw water desalination for chemical projects to make process pure water, suitable for feed water with trace colloids.
- Steel & Metallurgy Water Treatment: Desalination of raw water and recycled production water in steel and metallurgical plants to realize on-site water recycling.

Related Knowledge
Membrane Module Storage
System storage instructions:
- Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.
- Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.
- If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.
- If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.
- If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below 3. The preservative solution shall be renewed every month.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Fouling-Resistant BWRO Membrane Element, China Fouling-Resistant BWRO Membrane Element manufacturers, suppliers, factory, Acid Resistant RO Membrane, ro membrane multistage module, ro membrane polyamide module, ro membrane post treatment module, spiral wound membrane modular system, spiral wound membrane pressure driven module