Fouling Resistant Reverse Osmosis Membrane

Brand Name: NANOIMP
OEM/ODM: Accept
Manufacturer: Yes
Delivery Time: 3-15 days
Shipping Support: Express / Sea/ Land
Place of Origin: Hangzhou, China
E-mail: lena.hu@nano-sepmer.com
Model: ROB-8040/34FA | ROB-8040/46FA
Product Performance Parameters
|
Model |
ROB-8040/34FA | ROB-8040/46FA |
| Feed Spacer (mil) | 34 | 46 |
|
Membrane area (ft2/m2) |
400(37)±3% | 300(27)±3% |
|
Test desalination rate (%) |
99.5% |
|
|
Maximum operating temperature (℃) |
≤45 |
|
| Recommended Cleaning Pressure (psi/bar) | 75-100 / 5.2-6.9 | |
|
High operating pressure (psi/Mpa) |
≤600(41) |
|
| Single Element Pressure Differential (psi/bar) | 15(1.0) | |
|
Normal operation pH |
2-10 |
|
| Residual Chlorine Tolerance Concentration(ppm) | ≤0.1 | |
| Maximum Feed SDI | ≤5 | |
|
Test conditions |
2000 ppmNaCl , 25℃, pH=8, 15%Recovery rate, 225psi(1.55MPa) |
|
Product size parameters
(1) Flat End

|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
|
8040 |
1016 |
28.8 |
200 |
(2) Protruding End

|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
D (±0.1mm) |
| 2540 | 1016 | 30.2 | 19.1 | 61 |
|
4040 |
1016 |
26.7 |
19.1 |
100 |
Application Scenarios
- Surface / Groundwater Treatment: Purification of surface water and groundwater
- Industrial Wastewater Treatment: Treatment of production wastewater from steel, chemical, pharmaceutical and other industries, as well as printing and dyeing wastewater to meet discharge standards
- Reclaimed Water Reuse: Reuse of reclaimed water after treatment of municipal sewage and industrial wastewater to reduce energy consumption
- Landfill Leachate Treatment: Advanced treatment of leachate to meet discharge standards

Related Knowledge
Membrane Module Storage
System storage instructions:
- Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.
- Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.
- If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.
- If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.
- If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below 3. The preservative solution shall be renewed every month.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Fouling Resistant Reverse Osmosis Membrane, China Fouling Resistant Reverse Osmosis Membrane manufacturers, suppliers, factory, Acid Resistant RO Membrane, ro membrane multistage module, ro membrane polyamide module, ro membrane post treatment module, spiral wound membrane modular system, spiral wound membrane pressure driven module