Anti Acid Reverse Osmosis Membrane Element ASRO
Product size parameter
|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
D (±0.1mm) |
|
2540 |
1016 |
30.2 |
19.1 |
61 |
|
4040 |
1016 |
26.7 |
19.1 |
100 |
|
8040 |
1016 |
28.8 |
200 |
\ |


Application Scenarios
- Chemical acidic mother liquor recovery: Concentrate and purify acidic feed liquid in chemical workshops, cut wastewater discharge and realize material recycling.
- Acid mine wastewater treatment: Remove heavy metals and dissolved salts from acid mine drainage, reduce waste volume to meet local emission requirements.
- Special acidic process water reuse: Treat wastewater from phosphoric and sulfuric acid production lines for in-plant water recycling.
- New energy material production: Recover phosphoric acid and sulfuric acid generated during lithium battery wet dismantling and raw material processing.

Related Knowledge
Membrane Storage
Membrane elements are made of organic materials. Bacterial growth on the membrane surface can damage the active layer and result in loss of membrane performance. Therefore, if the membrane system will be shut down for a period of time, different preservation solutions shall be prepared and kept inside the system according to the downtime duration to prevent bacterial proliferation.
WARNING! Once the membrane module is wetted by water, it must be kept wet at all times. Drying out is strictly prohibited, otherwise the membrane sheet will be damaged and the membrane warranty terms will become invalid.
| Maximum Storage Duration | Preservation Solution |
| 3 days | Fill the system with deionized water. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 7 days | 0.1% V/V Proxel Gxl solution. After thorough mixing, adjust pH to 4.5–5.0 with citric acid, and circulate for 30 minutes at 10–25℃. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 30 days | 0.2% V/V Proxel Gxl solution. After thorough mixing, adjust pH to 4.5–5.0 with citric acid, and circulate for 30 minutes at 10–25℃. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 12 months | 0.25% V/V Proxel Gxl solution plus 18% V/V glycerol (98% reagent grade). After thorough mixing, adjust pH to 4.5–5.0 with citric acid, circulate for 60 minutes at 10–25℃. Renew the preservation solution every three months. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
The date when the reverse osmosis system is put into operation;
Six 6 months from the date the membrane elements are shipped from the manufacturing site;
Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Anti Acid Reverse Osmosis Membrane Element ASRO, China Anti Acid Reverse Osmosis Membrane Element ASRO manufacturers, suppliers, factory, sanitary membrane high hygiene module, sanitary membrane milk clarification module, sanitary membrane post treatment module, sanitary membrane protein separation module, sanitary membrane sanitary process system, sanitary membrane sterile water module