Heat Resistant Spiral RO Membrane | HSRO

Brand: NANOIMP
OEM & ODM: Available
Manufacturer: Available
Lead Time: 3-15 days
Shipping Method: Express / Sea / Land
Origin: Hangzhou, China
Email: lena.hu@nano-sepmer.com
Technical Specifications
| model | HSRO-8040/34SU | HSRO-8040/46SU |
| Membrane Area(ft2/m2) | 365(34)±3% | 290(27)±3% |
| Cleaning Temp. (℃) | 90 | |
| Continuous Operating pH Range | 2-11(Temp.<45℃) | |
| 3-8(Temp.<70℃) | ||
| Initial Salt Rejection (%) | 98.5%(NaCl) | |
| Customizable Sizes | 1812/4038/4040/8038/8040 | |
Application Fields
- High-temperature pure water production for industrial circulating systems
- Steam condensate recovery to realize heat and water resource recycling
- Concentration of glucose, high fructose syrup and other dilute sugar liquids
- Concentration process of heat-sensitive chemical raw feed solutions
- Purified process water and cleaning water for pharmaceutical production lines

Related Knowledge
Types of Membrane Fouling
Adsorption Fouling
Organics adsorb onto the membrane surface. Contaminants build up within membrane pores, shrinking pore size and raising membrane resistance. This fouling is difficult to remove. Main contaminants are dissolved substances and emulsions.
Scaling Fouling
Salts in raw water exceed solubility and precipitate as scale on membranes. Contaminants include colloids and particles: organics like fats, proteins and humic acid; inorganics such as calcium, magnesium, iron and phosphorus salts.
Biofouling
Microbes accumulate at the membrane-water interface in two phases: adhesion and growth. If biocide dosage is insufficient, attached microbes feed on nutrients and multiply to form biofilms, mainly bacteria and algae.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Heat Resistant Spiral RO Membrane | HSRO, China Heat Resistant Spiral RO Membrane | HSRO manufacturers, suppliers, factory, Anti Fouling RO 8040, reverse osmosis membrane, ro membrane low salinity module, ro membrane skid mounted system, spiral wound membrane permeate channel module, spiral wound membrane pressure driven module