Fouling Resistant BW Reverse Osmosis Membrane Element
Application Scenarios
- Purification of surface water and brackish groundwater: Treat slightly polluted surface water and brackish groundwater, remove dissolved salts, colloidal substances and suspended solids for industrial process water supply.
- Reuse of cooling tower blowdown: Deep desalination treatment for cooling tower discharge water from power and chemical industries. Permeate can return to circulating water systems to lower freshwater intake.
- Reclaimed water reuse for cities and industrial zones: Further desalinate municipal secondary effluent and industrial park recycled water to produce industrial pure water for production.
- Boiler feed water preparation for power plants: Desalinate and purify raw water to make boiler feed water and support stable generator operation.
- Process water for chemical and coal chemical industries: Raw water desalination for chemical facilities to generate process pure water, fit for feed water with low colloid content.
- Water treatment for steel and metallurgy sectors: Desalinate raw water and recycled production water in steel and metallurgical workshops to realize local water recycling.

Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
The date when the reverse osmosis system is put into operation;
Six 6 months from the date the membrane elements are shipped from the manufacturing site;
Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Related Knowledge
Membrane Module Storage
System storage instructions:
Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.
Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.
If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.
If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.
If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below 3. The preservative solution shall be renewed every month.
Hot Tags: Fouling Resistant BW Reverse Osmosis Membrane Element, China Fouling Resistant BW Reverse Osmosis Membrane Element manufacturers, suppliers, factory, Acid Resistant RO 8040, Heat Sanitizable Reverse Osmosis Membrane, HSRO 8040, ro membrane low fouling module, ro membrane separation module, spiral wound membrane permeate channel module