Wide pH Acid Stable RO Membrane Element
Technical Performance Indexes
|
model |
ASRO-8040/34FO |
ASRO-8040/46FO |
|
Membrane area (ft2/m2) |
365(34)±3% |
300(27)±3% |
|
Acid concentration tolerance |
Phosphorus: ≤15% hydrochloric/sulfuric acid: ≤10% |
|
|
Maximum operating temperature (°C) |
≤40 |
|
|
Maximum operating pressure (psi/bar) |
≤1305(90) |
|
|
Normal operation pH |
1-7 |
|
|
Customizable size |
2540/4040/8040 |
|
Dimension & Size Data
|
Membrane element size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
D (±0.1mm) |
|
2540 |
1016 |
30.2 |
19.1 |
61 |
|
4040 |
1016 |
26.7 |
19.1 |
100 |

Working Scenarios
- Reuse of factory wastewater: Apply advanced treatment to diverse production effluents and obtain standard recycled water for manufacturing lines, lowering raw water demand and sewage output
- Urban recycled water utilization: Recondition biotreated municipal sewage to create non-potable reclaimed water for gardening, road cleaning and toilet water supply
- High concentration treatment for high-salinity effluent: Condense salty wastewater from chemical and electroplating processes to reduce liquid volume and cut the cost of follow-up evaporation & crystallization
- Electroplating rinse water treatment: Concentrate electroplating washing water to retrieve heavy metal materials, and the permeate is available for repeated rinsing operations
- Power plant brine reduction: Secondary concentration of RO concentrated water from power stations to maximize water reuse and reduce brine emission
- Landfill leachate advanced finishing: Carry out deep polishing after the secondary treatment stage of landfill leachate

Related Knowledge
Membrane Storage
Membrane elements are made of organic materials. Bacterial growth on the membrane surface can damage the active layer and result in loss of membrane performance. Therefore, if the membrane system will be shut down for a period of time, different preservation solutions shall be prepared and kept inside the system according to the downtime duration to prevent bacterial proliferation.
WARNING! Once the membrane module is wetted by water, it must be kept wet at all times. Drying out is strictly prohibited, otherwise the membrane sheet will be damaged and the membrane warranty terms will become invalid.
| Maximum Storage Duration | Preservation Solution |
| 3 days | Fill the system with deionized water. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 7 days | 0.1% V/V Proxel Gxl solution. After thorough mixing, adjust pH to 4.5–5.0 with citric acid, and circulate for 30 minutes at 10–25℃. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 30 days | 0.2% V/V Proxel Gxl solution. After thorough mixing, adjust pH to 4.5–5.0 with citric acid, and circulate for 30 minutes at 10–25℃. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
| 12 months | 0.25% V/V Proxel Gxl solution plus 18% V/V glycerol (98% reagent grade). After thorough mixing, adjust pH to 4.5–5.0 with citric acid, circulate for 60 minutes at 10–25℃. Renew the preservation solution every three months. Add 18% V/V glycerol mixture if ambient temperature is below 0℃. |
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: Wide pH Acid Stable RO Membrane Element, China Wide pH Acid Stable RO Membrane Element manufacturers, suppliers, factory, ro membrane low fouling module, ro membrane separation module, ro membrane skid mounted system, ro membrane solute rejection module, spiral wound membrane permeate channel module, spiral wound membrane skid mounted system