E-Coat UF Membrane Element

Trade Name: NANOIMP
Production Supplier: Yes
Shipment Period: 3 to 15 days
Transport Modes: Express delivery, Sea shipment, Truck freight
Production Base: Hangzhou, China
Email Address: lena.hu@nano-sepmer.com
Primary Part Numbers: EUF-8240 | EUF-8040 | EUF-4040
Technical Performance Indicators
|
Membrane type |
Effective area (ft2/m2) |
Pure water flux (GPD/m³·d) |
MWCO (Da) |
|
EUF-8240 |
387(36) |
6500(26) |
10 0000 |
|
EUF-8040 |
365(34) |
6000(24) |
10 0000 |
|
EUF-4040 |
91(8.4) |
1800(7.2) |
10 0000 |
Dimension Specifications
|
Membrane Element Size |
A (±2.0mm) |
B (±0.1mm) |
C (±0.5mm) |
|
8240 |
1016 |
28.8 |
209 |
|
8040 |
1016 |
28.8 |
200 |

Suitable Use Cases
- Automotive and component coating: Applied in electrocoating lines for vehicle bodies, chassis and auto accessories. It helps reclaim electrophoretic paint and keep the coating bath stable.
- Home appliance coating operations: Suitable for electrophoretic primer coating of housings for refrigerators, laundry machines and air conditioning units.
- Construction and farm machinery: Designed for electrocoating treatment on farm equipment, transformers and heavy machinery parts.
- Hardware and metal goods: Supports electrocoating processes for hinges, sliding rails, metal furniture and fastening pieces.
- New energy metal assemblies: Used in electrophoretic coating lines for power battery casings and energy storage metal base materials.

Related Knowledge
Membrane Module Storage
System storage instructions:
- Uninstalled membrane modules must be stored at 5~40°C. Do not remove the outer packaging. Maximum storage period is 6 months, counted from the date of manufacture.
- Once the membrane is wetted, it shall remain wet at all times. Do not allow the membrane to dry out after commissioning.
- If the system shuts down for 24 hours, the liquid inside the membrane modules must be thoroughly flushed out.
- If the system remains out of service for 5 days, perform low-pressure flushing with clean water once per day.
- If the system shutdown exceeds 5 days, complete a cleaning procedure to drain the liquid from the modules. Then fill the modules with preservative solution containing 1% sodium bisulfite. (Prepare the preservative solution in the cleaning tank and circulate it through the modules by pump.) Check the pH value of the preservative solution weekly. Replace the solution when pH drops below. The preservative solution shall be renewed every month.
Warranty Period
The company warrants the performance of membrane elements for three 3 years. The three-year warranty period shall commence on the earliest of the following dates:
- The date when the reverse osmosis system is put into operation;
- Six 6 months from the date the membrane elements are shipped from the manufacturing site;
- Three 3 months after the membrane elements are shipped from Guangzhou / Shanghai, China to Taiwan of China, Japan, South Korea, Thailand, India, Malaysia, the United States and other designated locations in China.
Hot Tags: E-Coat UF Membrane Element, China E-Coat UF Membrane Element manufacturers, suppliers, factory, sanitary membrane, Sanitary Spiral NF Membrane, Sanitary Spiral RO Membrane, Sanitary Spiral UF Membrane 0 22 m